CCL Featured Stories, Homepage Featured Stories, Special Communication
Changes to RETAB, IA2AB, and PNHPNL Testing
Special Communication
Reticulin IgA and IgG Antibodies (RETAB)
Changes will be in effect on December 31, 2018.
Specimen Requirements
Volume:
0.8 mL, serum
Minimum Volume:
0.4 mL, serum
Collection Container:
Gold BD Hemogard™ Serum Separation Tube (SST)™
Alternate Container:
Red BD Hemogard™ Serum Tube (No Additive)
Specimen Instructions:
Centrifuge the specimen, then aliquot serum into a standard, non-sterile Aliquot Tube.
Transport Temperature:
Refrigerated
Insulinoma-Associated Antibody 2 (IA2AB)
Changes will be in effect on January 11, 2019.
Specimen Requirements
Volume:
0.5 mL, serum
Minimum Volume:
0.1 mL, serum
Collection Container:
Gold BD Hemogard™ Serum Separation Tube (SST)™
Transport Temperature:
Frozen
Stability
Ambient:
8 hours
Refrigerated:
48 hours
Frozen:
14 days
Other Information
Methodology:
Enzyme-Linked Immunosorbent Assay (ELISA)
Reference Range:
< 7.5 U/mL
Paroxysmal Nocturnal Hemoglobinuria (PNH) Panel by FCM (PNHPNL)
Changes will be in effect on January 15, 2019.
Stability
Ambient:
48 hours
Refrigerated:
Unacceptable
Frozen:
Unacceptable
Any additional information regarding this testing will be included in a future Technical Update.
If you have any questions about this change, please contact Client Services for assistance.