Targeted Oncology Panel Next Generation Sequencing Bone Marrow




Test Mnemonic

TOPBM

CPT Codes

  • 81455 - QTY (1)

Performing Laboratory

Cleveland Clinic Laboratories


Specimen Requirements

Volume Type Container Collect Temperature Transport Temperature Special Instructions
2 mLAspirate, bone marrowEDTA (Lavender)AmbientAmbient 

Stability

Environmental Condition Description
AmbientStable at ambient temperature for 48 hours.
RefrigeratedRefrigerate at 2 - 8C for up to 7 days.
FrozenUnacceptable

Days Performed

3 days per week

Turnaround Time

8 days

Methodology

Name Description
Next Gen Sequencing 

Special Info

The following genes are interrogated: ABL1, AKT, AKT1, AKT3, AR, AXL, BRAF, C11orf95, CCND1, CDK4, CDK6, CTNNB1, DDR2, EGFR, ERBB2, ERBB3, ERBB4, ERG, ESR1, ETV1, ETV4, ETV5, FGFR1, FGFR2, FGFR3, FGFR4, GNA11, GNAQ, GNAS, H3-3A, H3-3B, HRAS, IDH1, IDH2, JAK1, JAK2, JAK3, KIT, KRAS, MAP2K1, MAP2K2, MET, MTOR, MYC, MYCN, NRAS, NTRK1, NTRK2, NTRK3, PDGRFA, PIK3CA, PPARG, RAF1, RELA, RET, ROS1, SMO, TERT AND TP53.

Clinical Info

This pan-cancer assay evaluates tumor hotspots, SNVs, indels, CNVs, and gene fusions from DNA and RNA. This information can be used for diagnostic, prognostic and therapeutic purposes across a variety of solid and liquid tumors.