Copper, Free, Serum or Plasma




Test Mnemonic

FRCOP

CPT Codes

  • 82525 - QTY (1)

Includes

  • Copper, Free, Serum/Plasma

Performing Laboratory

ARUP


Specimen Requirements

Volume Type Container Collect Temperature Transport Temperature Special Instructions
3 mLSerumNo additive (Navy Blue) RefrigeratedDraw 2 tubes to ensure adequate serum/plasma volume. Do not use serum separator tubes. Remove serum from cells ASAP or within 2 hours of collection and aliquot into a trace metal-free transport tube (ARUP #43116) or acid-washed transfer vial (ARUP #54350).

Alternate Specimen Requirements

Volume Type Container Collect Temperature Transport Temperature Special Instructions
3 mLPlasmaEDTA (Royal blue) RefrigeratedDraw 2 tubes to ensure adequate serum/plasma volume. Do not use plasma separator tubes. Remove plasma from cells ASAP or within 2 hours of collection and aliquot into a trace metal-free transport tube (ARUP #43116) or acid-washed transfer vial (ARUP #54350).

Minimum Specimen Requirements

Volume Type Container Collect Temperature Transport Temperature Special Instructions
1.2 mL     

Stability

Environmental Condition Description
Ambient1 month
Refrigerated1 month
Frozen1 month

Days Performed

Varies

Turnaround Time

8 - 12 days

Methodology

Name Description
Inductively Coupled Plasma / Mass Spectrometry (ICP-MS) 

Reference Range

Special Info

Draw 2 tubes to ensure adequate serum/plasma volume. Separator tubes are unacceptable. This test is New York DOH approved.