Short Tandem Repeat Analysis for Specimen Identification, Other




Test Mnemonic

STRIDO

CPT Codes

  • 81265 - QTY (1)

Aliases

  • STR

Performing Laboratory

Cleveland Clinic Laboratories


Specimen Requirements

Volume Type Container Collect Temperature Transport Temperature Special Instructions
OneParaffin block, formalin fixedFormalin-fixed, paraffin-embedded blockN/AAmbientCut 5 charged, unbaked slides, 4um thick. Pre H&E slides must be examined. Known or unknown area will be microdissected from USS. Specimens that undergo heavy metal fixation or are decalcified with strong acids (i.e., formic acid) are not acceptable for molecular testing. Non-decalcified specimens or samples that undergo EDTA decalcification are acceptable.

Alternate Specimen Requirements

Volume Type Container Collect Temperature Transport Temperature Special Instructions
No Minimum VolumeTissue, fresh or frozenSterile containerAmbient or FrozenAmbient or Frozen 
OneSwab, buccalBuccal SwabAmbientAmbient 

Stability

Environmental Condition Description
AmbientAmbient only is acceptable.

Days Performed

2 days per week

Turnaround Time

7 days

Methodology

Name Description
Capillary Electrophoresis (CE) 
Polymerase Chain Reaction (PCR)